  1. 结论以水凝胶弹簧圈为材料的超选择性肾动脉栓塞术是治疗肾损伤一种安全有效的方法。

    Conclusion Ultraselective renal artery embolization with hydrogel spring coil is safe and effective in the treatment of kidney injury .

  2. 其中14例经8F导引管置入Magic-BD导管,采用可脱式球囊闭塞颈内动脉破口及颈内动脉,或经5F造影导管送入金属弹簧圈闭塞同侧颈内动脉。

    In 14 patients the homolateral internal carotid arteries were occluded by positioning Magic-BD catheter and ballon to the arterial rupture site or transplanting metallic spring coil via 5F catheter .

  3. 目的评价Matrix弹簧圈栓塞颅内破裂动脉瘤的安全性。

    Objective To evaluate the safety of embolization of ruptured intracranial aneurysms with matrix coils .

  4. Matrix可脱弹簧圈作为血管内治疗脑内血管瘤的新方法:早期血管造影和临床预后的分析

    Matrix detachable coils for the endovascular treatment of intracranial aneurysms : Analysis of early angiographic and clinical outcomes

  5. Matrix弹簧圈是为了防止动脉瘤再通而设计的新型药物涂层微弹簧圈,其表面覆盖有生物活性物质,能够促进动脉瘤内血栓组织化和纤维愈合。

    Matrix coil , biologically active material coated platinum coils , was designed to decrease the rate of recanalization .

  6. 目的探讨Matrix电解弹簧圈栓塞治疗颅内动脉瘤的疗效、技术要点、并发症的原因以及防治方法。

    Objective To explore the efficacy , technique and complication of endovascular embolization in intracranial aneurysms with Matrix detachable coils .

  7. 三维CT血管造影在电解脱弹簧圈栓塞急性破裂脑动脉瘤中的临床价值三维CT血管造影在颅内动脉瘤诊治中的应用

    The clinical value of three dimensional computed tomographic angiography in embolization of acutely ruptured intracranial aneurysms with Guglielmi detachable coil

  8. 对18例合并主动脉至肺动脉侧支血管的患儿以及5例BT分流术的患儿在外科根治术前采用弹簧圈进行侧支血管和分流管道的堵塞术;

    Transcatheter coil embolization was performed in18 children with systemic to pulmonary collateral vessels and5 children with B-T shunts before surgical procedures .

  9. 应用Cook可控弹簧圈关闭动脉导管未闭疗效探讨

    Closure of Patent Ductus Arterious with Cook Detachable Coil

  10. LEO自膨式支架结合水解脱弹簧圈栓塞治疗颅内宽颈动脉瘤

    Combination of LEO self-expandable stents implantation and hydro-detachable coils placement for intracranial wide-necked aneurysms

  11. 目的总结螺旋弹簧圈(Coil)堵塞术治疗先天性肺动静脉瘘的经验及疗效。

    Objective To analyze the efficacy and experience of coil embolization in patients with pulmonary arteriovenous malformations ( PAMV ) .

  12. 2例PDA均用弹簧圈封堵。

    PDA were closed with coils .

  13. 脑动脉瘤可脱落弹簧圈治疗术后随访MRA与DSA的对比研究

    MR angiography versus digital subtraction angiography in the follow-up of cerebral aneurysms treated with detachable coils

  14. 目的:探索Cook可控弹簧圈封堵动脉导管未闭(PDA)的疗效。

    Objective : To evaluate the effect of Cook detachable coil for closure of patent ductus arterious ( PDA ) .

  15. 方法总结经导管介入治疗(介入组)冠状动脉瘘17例,其中应用Cook公司非可控弹簧圈11例,可控弹簧圈2例;

    Methods Altogether 17 cases for intervention , included 13 using the Cook corp coil ( 2 detachable and another 11 un-detachable );

  16. 室间隔缺损(VSD)伴PDA采用弹簧圈封堵。

    For ventricular septal defect ( VSD ) and PDA , all occlusions with detachable coils .

  17. 结论对于囊状动脉瘤SAH急性期的病人,微弹簧圈动脉瘤腔内栓塞治疗是较为安全有效的方法。

    Conclusion Coil occlusion is a safe and effective method for treatment of ruptured aneurysm .

  18. 目的探讨经数字减影血管造影(DSA)行颅内动脉瘤电解可脱性弹簧圈(GDC)栓塞术的麻醉效果。

    Objective To investigate the effects of anesthesia GDC embolization operation for intracranial aneurysm through DSA .

  19. 6例A型病例经动脉途径进行球囊栓塞,1例C型病例及1例D型病例经静脉途径进行弹簧圈栓塞。

    Of all the 9 cases , 6 cases of A type were treated with detachable balloon through transarterial approach , one case of C type and one case of D type were treated with coils through transvenous approach .

  20. 电解可脱性弹簧圈(GDC)栓塞治疗颅内动脉瘤(附11例报告)

    Intracranial Aneurysm of Embolization Using Electrolytic Detachable Coil ( A Report of 11 Cases )

  21. 方法:对105个动脉瘤的3DDSA与2DDSA图像进行比较,分析动脉瘤的形状、瘤颈的显示、血管内治疗的可行性、血管内治疗的工作角度及第一枚弹簧圈大小的选择。

    Methods : In105 aneurysms , aneurysm shape , aneurysm neck , the feasibility of endovascular treatment and the selection of the first coil were analyzed at2D DSA and3D DSA .

  22. 前言:目的:总结电解可脱微弹簧圈(GDC)治疗急性期破裂颅内动脉瘤的经验。

    Objective : To evaluate GDC embolization therapy in treatment of acute stage of ruptured aneurysms .

  23. 目的探讨颅内动脉瘤应用电解可脱性弹簧圈(GDC)经血管内治疗的新方法。

    Objective To investigate the new technique in curing intracranial aneurysms with GDC via intravascular catheter .

  24. 结论在动脉瘤性SAH患者的血管内弹簧圈治疗中,总的术中穿破率为3%,死亡率为0.5%;

    Conclusion The rate of aneurysm rupture during coil embolization is 3 % and is responsible for 0.5 % of treatment-related deaths .

  25. 细胞培养试验观察弹簧圈上或其附近的大鼠动脉平滑肌细胞(A10)的转染。

    Cell culture studies with rat arterial smooth muscle cells ( A10 ) assessed transduction on or near the coil .

  26. 用电解可控弹簧圈(GDC、EDC)、游离弹簧圈和丝线等多种栓塞材料填塞病变侧海绵窦,同时闭塞瘘口。

    The embolizing materials included controllable coils ( GDC , EDC ), free coil , and silk .

  27. 两种单静脉法与传统Amplatzer法治疗动脉导管未闭应用Cook可控弹簧圈关闭动脉导管未闭疗效探讨

    Two single venous approachs and classical Amplatzer method for closure of patent ductus arterious with Amplatzer occluder Closure of Patent Ductus Arterious with Cook Detachable Coil

  28. 目的探讨螺旋CT血管造影(SCTA)对脑动脉瘤电解可脱弹簧圈(GDC)血管内栓塞治疗的指导价值。

    Purpose To evaluate the directive value of spiral CT angiography ( SCTA ) in the endovascular embolization of cerebral aneurysms with guglielmi detachable coil ( GDC ) .

  29. 目的应用电解式可脱性弹簧圈(GDC)血管内栓塞治疗颅内动脉瘤和医用生物胶NBCA栓塞治疗脑动静脉畸形的疗效观察。

    To evaluate the effect and the method of endovascular embolization of intracranial aneurysms and cerebral arterio venous malformations .

  30. 目的以微弹簧圈(MC)瘤腔栓塞治疗兔颈总动脉创伤性假性动脉瘤(TPA),评价其长期疗效。

    Objective : To evaluate the long-term effect of endovascular occlusion with microcoils ( MC ) of experimental traumatic pseudoaneurysm ( TPA ) in the common carotid artery in rabbits .